SmartPro line-interactive UPS system is ideal for voice, data, medical and industrial networking applications |
 |
Large internal batteries offer 27 minutes at half load (375VA/250W) and 10 minutes at full load (750VA/500w) |
 |
Runtime is expandable with optional BP24V28-2U (limit 1) and BP24V70-3U (no limit) external battery packs |
 |
Line-interactive automatic voltage regulation (AVR) maintains selectable 120V, 110V or 100V nominal output during brownouts as low as 83V and overvoltages to 145V |
 |
Network interfaces support simultaneous communications via built-in USB port, DB9 serial port and SNMPWEBCARD slot |
 |
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X |
 |
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP |
 |
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, timed inverter sutoff, activate self-test and output power control |
 |
NEMA 5-15P input plug; 8 battery-supported NEMA 5-15R output receptacles |
 |
Dataline surge suppression protects dialup, DSL or network Ethernet connection |
 |
Front panel LEDs offer current monitoring, voltage regulation and battery charge level information |
 |
UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required |
 |
2-year warranty; $250,000 Ultimate Lifetime Insurance (USA & Canada only) |
 |
|
 |
SYSTEM OVERVIEW |
|
 |
Voltage compatibility |
120V (110, 100V user selectable) |
 |
Frequency compatibility |
60 Hz |
 |
OUTPUT |
|
 |
Output VA |
750 |
 |
Output watts |
500 |
 |
Output nominal voltage |
120, 110, 100V AC |
 |
Output voltage regulation |
LINE MODE: Sine wave line voltage 120V (+6%, -10%), 110V (+6%, -10%), 100V (+6%, -10%), BATTERY MODE: Sine wave output 120V, 110V, 100V (+/-5%) |
 |
Output frequency regulation |
LINE MODE: Passes line frequency of +/-10% BATTERY MODE: Inverter output regulated to 60Hz (+/- 1Hz) |
 |
Outlet quantity / type |
8 NEMA 5-15R |
 |
INPUT |
|
 |
Maximum input amps |
5.4A (120V), 5.8A (110V), 6.4A (100V) |
 |
Input connection type |
NEMA 5-15P |
 |
Input cord length |
6 ft. |
 |
Recommended electrical service |
120V 15A |
 |
BATTERY |
|
 |
Full load runtime |
10 minutes (500w) expandable |
 |
Half load runtime |
27 minutes (250w) expandable |
 |
Expandable battery runtime |
Runtime is expandable with BP24V28-2U (limit 1) or BP24V70-3U (multi-pack compatible) |
 |
DC system voltage |
24VDC |
 |
Battery recharge rate |
4.5 hour recharge to 90% (max) |
 |
Replacement Battery Cartridge |
RBC24-SLT |
 |
VOLTAGE REGULATION |
|
 |
Voltage regulation description |
Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120, 110, 100V nominal output, without using battery power, during brownouts 95V (120V), 87V (110V), 83V (100V) |
 |
Overvoltage correction |
Input voltages between 127 and 145V (120V), 116 and 133 (110V), 111 and 121 (100V) are reduced by 12% |
 |
Brownout correction |
Input voltages between 95 and 108 (120V), 87 and 99 (110V), 83 and 93 (100V) are boosted by 14% |
 |
LEDS ALARMS & SWITCHES |
|
 |
Front panel LEDs |
Includes front panel LEDs to indicate line / battery power status, over / under voltage correction, battery charge level, load percentage, overload, wiring fault and replace battery. |
 |
Alarms |
Audible alarm warns of power failure condition |
 |
Switches |
Includes two pushbutton switches for on/off power control and self-test/ alarm cancel functions. Also includes two dipswitch controls for setting the nominal voltage |
 |
SURGE / NOISE SUPPRESSION |
|
 |
AC surge suppression |
570 joules |
 |
AC suppression response time |
Instantaneous |
 |
Dataline suppression |
Includes 8-wire RJ45 jack; pins 1, 2, 3 and 6 provide 10baseT Ethernet line surge suppression with 7.5V clamping; pins 4 and 5 provide single-line tel/DSL line surge suppression starting at 260V |
 |
EMI / RFI AC noise suppression |
Yes |
 |
PHYSICAL |
|
 |
Shipping weight (lbs) |
37 |
 |
Shipping weight (kg) |
16.8 |
 |
Shipping Dimensions (HWD/in) |
13 x 10 x 23.75 |
 |
Shipping Dimensions (HWD/cm) |
33 x 25.4 x 60.3 |
 |
Unit weight (lbs) |
33.9 |
 |
Unit weight (kg) |
15.4 |
 |
Unit Dimensions (HWD/in) |
10.1 x 6.7 x 13.8 |
 |
Unit Dimensions (HWD/cm) |
25.7 x 16.9 x 35.1 |
 |
Material of construction |
Steel |
 |
Form factors supported |
Tower |
 |
Cooling method |
Fan |
 |
Battery Access |
Supports battery access and hot-swap replacement without powering connected equipment off |
 |
ENVIRONMENTAL |
|
 |
Relative Humidity |
0 to 95%, non-condensing |
 |
COMMUNICATIONS |
|
 |
Network monitoring port |
Includes 2 built-in monitoring ports, 1 USB and 1 DB9. Each supports on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity and line frequency status messaging. |
 |
Software and cabling included |
Includes PowerAlert UPS monitoring software for all common network and stand-alone operating systems. Ships with 2 cables, 1 USB and 1 DB9 |
 |
SNMP compatibility |
SNMP adapter accessory # SNMPWEBCARD |
 |
WatchDog compatibility |
Compatible with Tripp Lite's WatchDog Software to restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment; ideal for unattended kiosk applications |
 |
LINE / BATTERY TRANSFER |
|
 |
Transfer time from line power to battery mode |
4 milliseconds (typical) |
 |
Low voltage transfer to battery power |
Switches to battery power as line voltage decreases to 95V (120V), 87V (110V) , or 83V (100V) or less. Resets back to line power mode as line voltage increases to 100V (120V), 92V (110V), or 87V (100V) or higher |
 |
High voltage transfer to battery power |
Switches to battery power as line voltage increases to 145V (120V), 133V (110V), and 121V (100V) volts or higher. Resets back to line power mode as line voltage decreases to 141 (120V), 129 (110V), or 118V (100V) or less |
 |
CERTIFICATIONS |
|
 |
Certifications |
Tested to UL1778 (USA), CSA (Canada), RoHS Compliant, Class B (Emissions), NOM (Mexico), FCC Part 68 / Industry Canada (telecommunications) |
 |
WARRANTY |
|
 |
Product warranty |
2 years |
 |
Connected equipment insurance (USA and Canada Only |
$250,000 |
 |
Optional coverage |
3-5 year warranties, plus next day and on-site warranty coverage available for select opportunities. Contact Tripp Lite for additional information |
 |
SPECIAL FEATURES |
|
 |
Cold Start |
Yes, inverter can be "cold started" to enable temporary AC output during a power failure by pressing and holding the POWER ON button for longer than 1 second. |
 |
Appearance |
Attractive all-black tower UPS |
 |
BATTERY PACK ACCESSORY (optional) |
|
 |
Battery Pack Accessory (optional) |
BP24V28-2U (limit 1), BP24V70-3U (multi-pack compatible |