OUTPUT |
 |
Output Volt Amp Capacity (VA): 750 |
 |
Output kVA capacity (kVA): .75 |
 |
Output Watt Capacity (watts): 675 |
 |
Output power factor: 0.9 |
 |
Output Capacity Details: |
 |
ON LINE MODE: Maximum output capacity ratings are reduced for some nominal voltage settings (127/120/115/110V 675 watts, 100V 608 watts). FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120/115/110V 472 watts / 100V 425 watts). |
 |
Crest Factor: 3:1 |
 |
Nominal Output Voltage(s) Supported: 100V; 110V; 115V; 120V; 127V |
 |
Nominal Voltage details: 120V factory-default nominal voltage |
 |
Frequency compatibility: 50/60 Hz (auto-selectable); Supports 50 to 60 Hz and 60 to 50 Hz conversion |
 |
Frequency compatibility details: |
 |
ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz. |
 |
Output voltage regulation (line mode) : +/- 2% |
 |
Output voltage regulation (Economy line mode) : +/- 10% |
 |
Output voltage regulation (Battery mode) : +/- 3% |
 |
Built-in UPS output receptacles: 6 5-15R outlet(s) |
 |
Built-in controllable switched load banks: Two switchable single-outlet 5-15R load banks |
 |
Output AC waveform: Pure Sine wave |
 |
INPUT |
 |
Rated input current (at maximum load): 8A |
 |
Nominal Input Voltage(s) Supported: 100V AC; 110V AC; 115V AC; 120V AC; 127V AC |
 |
Nominal input voltage description: 120V factory default |
 |
UPS input connection type: 5-15P |
 |
Input circuit breaker: 15A |
 |
UPS Input cord length (ft.) : 10 |
 |
UPS Input cord length (m) : 3 |
 |
Recommended Electrical Service: 15A 120V |
 |
BATTERY |
 |
Full load runtime (minutes) : 3 min. (675w) |
 |
Half load runtime (minutes) : 9 min. (337.5w) |
 |
Expandable battery runtime: Extended runtime supported via optional external battery packs |
 |
External battery pack compatibility: BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) |
 |
Expandable runtime description: Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details |
 |
DC system voltage (VDC) : 24 |
 |
Battery recharge rate (included batteries) : Less than 3 hours recharge to 90% |
 |
Replacement battery cartridge (internal UPS battery replacement) : RBC24V-LCD |
 |
Battery Access: Front panel battery access |
 |
Battery replacement description: Hot-swappable, user replaceable batteries |
 |
VOLTAGE REGULATION |
 |
Voltage regulation description: Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages |
 |
Overvoltage correction: Corrects overvoltages to 150V (0-100% load) |
 |
Undervoltage correction: Corrects undervoltages to 100V at full load (90V at 100V nominal) |
 |
Severe undervoltage correction: Corrects brownouts to 70V (70% load) & 55V (33% load) |
 |
LEDS ALARMS & SWITCHES |
 |
LED Indicators: 7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status |
 |
Front panel LCD display: Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options |
 |
Alarms: Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
 |
Alarm cancel operation: Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
 |
Switches: 2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options |
 |
SURGE / NOISE SUPPRESSION |
 |
UPS AC suppression joule rating: 570 |
 |
UPS AC suppression response time: Instantaneous |
 |
UPS Dataline suppression: 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
 |
EMI / RFI AC noise suppression: Yes |
 |
PHYSICAL |
 |
Installation form factors supported with included accessories: 4 post 19 inch rackmount (mounting rail kit included) |
 |
Installation form factors supported with optional accessories: 2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) |
 |
Primary form factor: Rackmount |
 |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) : 3.5 x 17.5 x 12.5 |
 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) : 8.9 x 44.4 x 31.8 |
 |
Installed whole system total rack space height (rack spaces) : 2U |
 |
Secondary form factor: Tower (requires 2-9USTAND) |
 |
UPS / Power Module weight (lbs) : 27.6 |
 |
UPS housing material: Steel |
 |
Cooling method: Fan |
 |
ENVIRONMENTAL |
 |
Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
 |
Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
 |
Relative Humidity: 0 to 95%, non-condensing |
 |
AC mode BTU / hr. (full load) : 341 |
 |
AC economy mode BTU / hr. (full load) : 230 |
 |
Battery mode BTU / hr. (full load) : 585 |
 |
AC economy mode efficiency rating (100% load) : 93% |
 |
Operating Elevation (ft) : 0-3000m / 0-10,000 ft. |
 |
Audible Noise: 45 dBA at 1m front side |
 |
COMMUNICATIONS |
 |
Communications interface: USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |
 |
Network monitoring port description: Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications |
 |
PowerAlert software: Included |
 |
Communications cable: USB and DB9 cabling included |
 |
WatchDog compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications |
 |
LINE / BATTERY TRANSFER |
 |
Transfer time: Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode |
 |
Low voltage transfer to battery power (setpoint) : 100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load |
 |
High voltage transfer to battery power (setpoint) : 150 |
 |
SPECIAL FEATURES |
 |
Cold Start (startup in battery mode during a power failure) : Cold-start operation supported |
 |
High availability UPS features: Automatic inverter bypass; Hot swappable batteries |
 |
Green & high efficiency features: High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy mode operation |
 |
CERTIFICATIONS |
 |
UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); ROHS (Restriction of Hazardous Substances) |
 |
WARRANTY |
 |
Product Warranty Period (Worldwide) : 2-year limited warranty |
 |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) : $250,000 Ultimate Lifetime Insurance |