Sold Out
This product is currently not available.
advertisement
Earn Super Points: Write a Review
Sold Out!
Sorry, this selection is currently unavailable.
X-Rite i1 Photo Pro 2 1 of 1
Share
promo
 
Description
 

Learn more about X-Rite i1 Photo Pro 2:

Mfg Part#: EO2PHO
Sku: 230395507
See more in Software Suites
 
i1Photo Pro 2 offers the most accurate and consistent color calibration and profiling from capture to view to print. i1Photo Pro 2 combines world-class hardware and software to deliver the ultimate professional level color management for photo pros.

Features

Video Features New illuminant design allows for 3 standard measurement conditions (ISO 13655 M0: Tungsten; ISO 13655 M1: D50; ISO 13655 M2: UV Cut) plus Optical Brightener Compensation (OBC) without changing filters or needing a second instrument and ensures your investment well into the future.

Video Features Enhanced Optical Brightener Compensation allows for the most accurate profiling for today’s enhanced range of substrates. Now photographers can predict what colors printed on optically brightened paper will look like under both standard and specific light conditions using a single hand-held device.

Video Features Positioning Detection Sensor provides a more robust scanning experience even on special substrates and low-resolution printers. It allows for the measurement of smaller patch sizes (as low as 7mm) in manual mode saving time and money on consumables and enabling dual measurement workflows for OBC, M1 and M2.

Video Features New Status LED guides users through the measurement process and provides feedback on device status, improving the user experience and saving time.

Video Features New Design Ergonomics throughout allows for greater usability, flexibility, cleaning, protection, and storage of the precision i1Pro 2 device, assuring the highest level of reliability and productivity.

Video Features Better temperature stability and higher brightness levels improve emissive measurement, resulting in the best possible calibration and profiling of monitors and projectors.

Video Features All new diagnostics and self-correction features: Built-in wavelength calibration technology allows for self-diagnosis of optical grating in relation to sensor during white calibration (with automatic correction and notifications) eliminating worry about your device’s measurement accuracy.

Video Features Maintaining and protecting the device (and investment) is easier than ever: Self-cleanable aperture protection glass and calibration white tile cover provides additional built-in protection from dust and dirt keeping your device working at top performance at all times.

Video Features XRGA equipped: i1Pro 2 is equipped with the X-Rite Graphic Arts Standard (XRGA) to make it quicker and easier for companies and professionals involved in digital production printing to adhere to ISO standards and have confidence that data sent or received from all links in the supply chain is reliable and repeatable.

Video Features i1PHOTO PRO 2 INCLUDES:
Video Features i1Pro 2 spectrophotometer (measurement device)
Video Features Calibration plate
Video Features Ambient light measurement head
Video Features Monitor holder
Video Features Positioning target
Video Features Scanning ruler
Video Features Backup board
Video Features USB cable
Video Features i1Profiler v1.x software for monitors
Video Features Projectors and RGB printers
Video Features ColorChecker Camera Calibration software
Video Features PANTONE Color Manager software
Video Features ColorChecker Classic target [mini]
Video Features ColorChecker Proof target
Video Features Soft-sided storage case.

Tech Specs

Tech Specs i1Profiler Software Specifications
Tech Specs Macintosh®
Tech Specs MacOS X 10.5.8, 10.6.x and 10.7.x (with the latest updates installed)
Tech Specs 1GB RAM
Tech Specs Intel® Processor
Tech Specs Up to 2GB of available disk space (depending on components installed)
Tech Specs Powered USB Port
Tech Specs Monitor resolution of 1024x768 pixels or higher
Tech Specs Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded
Tech Specs DVD drive or high-speed internet connection required for software install, download and automatic software update

Tech Specs Windows®
Tech Specs Microsoft® Windows® XP® 32 bit (with latest Service Packs and updates installed) Microsoft® Windows Vista® 32 or 64 bit (with latest Service Packs and updates installed)
Tech Specs Microsoft® Windows 7® 32 or 64 bit (with latest Service Packs and updates installed)
Tech Specs 1GB RAM
Tech Specs Intel® Pentium® IV or AMD® Athlon® XP or better CPU
Tech Specs Up to 2GB of available disk space (depending on components installed)
Tech Specs Powered USB Port
Tech Specs Monitor resolution of 1024x768 pixels or higher
Tech Specs Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded
Tech Specs Network adaptor installed and driver loaded
Tech Specs DVD drive or high-speed internet connection required for software install, download and automatic software update

Tech Specs LANGUAGE VERSIONS
Tech Specs This product is available in the following languages:
Tech Specs Chinese (Simplified)
Tech Specs English
Tech Specs French
Tech Specs German
Tech Specs Italian
Tech Specs Japanese
Tech Specs Portuguese
Tech Specs Spanish
Tech Specs Russian

Tech Specs i1Pro Hardware Specifications
Tech Specs SPECTRAL ENGINE
Tech Specs i1® technology with built-in wavelengths check
Tech Specs Spectral analyzer: Holographic diffraction grating with 128-pixel diode array
Tech Specs Spectral Range: 380 - 730 nm
Tech Specs Physical sampling interval: 3.5 nm
Tech Specs Optical resolution: 10 nm
Tech Specs Spectral reporting: 380 ... 730 nm in 10 nm steps
Tech Specs Measurement Frequency in scanning mode: 200 measurements per second

Tech Specs OPTICS
Tech Specs Measurement geometry: 45°/0° ring illumination optics, ISO 13655:2009
Tech Specs Measurement aperture: 4.5 mm (0.18”) diameter (effective measurement aperture during scanning is depending on the patch size and measurement speed)
Tech Specs Illumination Spot Size: 3.5 mm (0.14”)
Tech Specs Light source: Gas filled tungsten (illuminant type A) and UV LED

Tech Specs REFLECTANCE MEASUREMENT
Tech Specs Data Format: Spectral Reflectance [dimensionless]
Tech Specs Measurement Conditions:
Tech Specs UV included - ISO 13655:2009 measurement condition M0
Tech Specs D50 - ISO 13655:2009 measurement condition M1
Tech Specs UV excluded Filter - ISO 13655:2009 measurement condition M2
Tech Specs OBC: Optical Brightener Compensation (OBC) with i1Profiler software
Tech Specs Calibration: Manual on external ceramic white reference
Tech Specs Measurement Background: white, ISO 13655:2009; for measurements on backup board
Tech Specs Minimal Media Thickness: 3 mm (0.12”) on backup board
Tech Specs Minimal Patch Size in Scanning Mode: 7 x 10 mm (0.28” x 0.39”) (Width x Height) with sensor ruler 10 x 10 mm (0.39” x 0.39”) (Width x Height) without sensor ruler
Tech Specs Inter-instrument agreement: 0.4 ?E94* average, 1.0 ?E94* max. (deviation from X-Rite manufacturing standard at a temperature of 23ºC (73.4ºF) on 12 BCRA tiles (D50, 2º))
Tech Specs Short-term repeatability: 0.1 ?E94* on white (D50,2°, mean of 10 measurements every 3 seconds on white)